Kontakt Home Home

Laser Beam Shutters for Safety & Beam Control Applications

Beam Shutter

Gravity fed for fail safe operation

Combined shutter and beam dump for added safety

High quality engineering design

Specially designed for compatability with safety control systems

LED shutter status indication (output available for remote indication)

Interlocked safety shutdown or manual operation

Safety latch prevents accidental beam switch on

Remote switching option

Low current requirement

Also available as OEM product

LS-100-12-Aperture The LS- range of laser beam shutters are combined shutters and beam dumps designed to be driven by a safety control system such as the Lasermet ICS-1 laser interlock control system, for use as a means of shutting down the laser beam automatically during unauthorised access, or manually when the beam is not required. They can also be used as stand alone shutters for manual or remote switching of the beam, or are available as OEM components for laser or laser product manufacturers.

When used with the ICS-1 interlock control system the LS-shutters are used as shown below:




Beam Shutter Diagram

Opening of any laboratory door without use of the override will result in the shutter closing, thus preventing unprotected persons from exposure to the laser radiation. The shutter is fail safe and gravity fed. Loss of power will cause the shutter to close without reliance on springs or any other device. High quality engineering design ensures smooth and reliable operation.

Combined Shutter & Beam Dump

The LS- series shutters are designed to absorb all the laser beam power thus eliminating the need for an additional beam dump and avoiding hazardous reflections. The laser beam is converted to heat and radiated from the shutter case. Shutters can be used with lasers up to the maximum CW power specified. The LS-10-12 is suitable for up to 20 W average power. The LS-100-12 is air cooled by a fan and suitable for up to 200 W average power.

Low Current Requirement

Intelligent design results in low current consumption. This increases the number of shutters which can be run from the same power supply and keeps the shutter cool for use as a beam dump when closed.

Model

Max laser
power (W)

Aperture Size
(mm)

Drive
voltage
(V DC)

Drive voltage with
LS-VC-24.12 (V DC)

Current
consumption (mA)

Size (mm)

LS-10-12

20

15

11 - 14

15 - 35

150

98 x 63.5 x 36*

LS-100-12

200

50

11 - 14

15 - 35

150

130 x 150 x 140 *

* 100mm including tube
** 175mm including tube

Operating Voltage

All shutters work from 12 VDC (11 – 14 VDC). However, if your supply is 18, 24 VDC or similar request the LS voltage converter (part no.LS-VC-24.12) which enables operation from 15 – 35 VDC.

Operating Logic

The shutters will not open unless power is supplied. When power is supplied a yellow LED lights to indicate that power is present. A green LED will also light indicating that the shutter is fully closed. To open the shutter the green button must be pressed. The green LED will go out and an orange LED will light indicating that the shutter is fully open. The shutter can be closed by pressing the red button or by cutting the power.

Remote Switching Station for Beam ShuttersRemote Switching Station

For applications where the laser shutter is used in an enclosure and the buttons cannot be accessed, or for other remote switching requirements, the LS-RS can be used to open and close the shutter from a distance.

Switch Bypass Mode

Alternatively shutters can be put into ‘switch bypass mode’ by changing some internal links on the PCB inside the shutter. In this mode the shutter will open immediately when the power is applied and close when the power is turned off.

Remote Indication of Shutter Status

12 VDC outputs are available from the shutter to power remote LEDs indicating shutter status.

Remote Interlock Board

An optional interlock board (part no: LS-10-IB) can be fitted, providing two volt free contacts, one normally open and one normally closed, which can be used to interlock another device to the shutter status. These contacts are rated at 2A and 30 VDC.

Computer Interface

A computer interface device is currently under development. This will enable operation of the shutter from a computer via a USB connected device. Operation may be carried out by use of the standard software package provided, or by interfacing to other programs. Contact the Sales Department for advice on a release date.

Laser Shutter with Mounting Plate - UndersideFixings

The LS-10-12 has a single M6 thread in the base and can be mounted to a breadboard by use of an optical pin.
The LS-100-12 has four M6 mounting threads in the base. It can be mounted on a breadboard at any angle, by using mounting plate pack LS-100-MP and metric (LS-100-MAS) or imperial (LS-100-IAS) mounting screws.