Gravity fed for fail safe operation |
 |
Combined shutter and beam dump for added safety |
 |
High quality engineering design |
 |
Specially designed for compatability with safety control
systems |
 |
LED shutter status indication (output available for remote
indication) |
 |
Interlocked safety shutdown or manual operation |
 |
Safety latch prevents accidental beam switch on |
 |
Remote switching option |
 |
Low current requirement |
 |
Also available as OEM product |
The LS- range of laser beam
shutters are combined shutters and beam dumps designed to be driven by a safety
control system such as the Lasermet ICS-1 laser interlock control system, for
use as a means of shutting down the laser beam automatically during
unauthorised access, or manually when the beam is not required. They can also
be used as stand alone shutters for manual or remote switching of the beam, or
are available as OEM components for laser or laser product manufacturers.
When used with the ICS-1 interlock control system the LS-shutters
are used as shown below:

Opening of any laboratory door without use of the override will
result in the shutter closing, thus preventing unprotected persons from
exposure to the laser radiation. The shutter is fail safe and gravity fed. Loss
of power will cause the shutter to close without reliance on springs or any
other device. High quality engineering design ensures smooth and reliable
operation.
Combined Shutter & Beam Dump
The LS- series shutters are designed to absorb all the laser beam
power thus eliminating the need for an additional beam dump and avoiding
hazardous reflections. The laser beam is converted to heat and radiated from
the shutter case. Shutters can be used with lasers up to the maximum CW power
specified. The LS-10-12 is suitable for up to 20 W average power. The LS-100-12
is air cooled by a fan and suitable for up to 200 W average power.
Low Current Requirement
Intelligent design results in low current consumption. This
increases the number of shutters which can be run from the same power supply
and keeps the shutter cool for use as a beam dump when closed.
|
Model |
Max laser power (W) |
Aperture Size (mm) |
Drive voltage (V DC) |
Drive voltage with LS-VC-24.12 (V
DC) |
Current consumption (mA) |
Size (mm) |
|
LS-10-12 |
20 |
15 |
11 - 14 |
15 - 35 |
150 |
98 x 63.5 x 36* |
|
LS-100-12 |
200 |
50 |
11 - 14 |
15 - 35 |
150 |
130 x 150 x 140 * |
* 100mm including tube ** 175mm including tube
Operating Voltage
All shutters work from 12 VDC (11 14 VDC). However, if your
supply is 18, 24 VDC or similar request the LS voltage converter (part
no.LS-VC-24.12) which enables operation from 15 35 VDC.
Operating Logic
The shutters will not open unless power is supplied. When power is
supplied a yellow LED lights to indicate that power is present. A green LED
will also light indicating that the shutter is fully closed. To open the
shutter the green button must be pressed. The green LED will go out and an
orange LED will light indicating that the shutter is fully open. The shutter
can be closed by pressing the red button or by cutting the power.
Remote Switching Station
For applications where the laser shutter is used in an enclosure
and the buttons cannot be accessed, or for other remote switching requirements,
the LS-RS can be used to open and close the shutter from a distance.
Switch Bypass Mode
Alternatively shutters can be put into switch bypass
mode by changing some internal links on the PCB inside the shutter. In
this mode the shutter will open immediately when the power is applied and close
when the power is turned off.
Remote Indication of Shutter Status
12 VDC outputs are available from the shutter to power remote LEDs
indicating shutter status.
Remote Interlock Board
An optional interlock board (part no: LS-10-IB) can be fitted,
providing two volt free contacts, one normally open and one normally closed,
which can be used to interlock another device to the shutter status. These
contacts are rated at 2A and 30 VDC.
Computer Interface
A computer interface device is currently under development. This
will enable operation of the shutter from a computer via a USB connected
device. Operation may be carried out by use of the standard software package
provided, or by interfacing to other programs. Contact the
Sales Department for advice on
a release date.
Fixings
The LS-10-12 has a single M6 thread in the base and can be mounted
to a breadboard by use of an optical pin. The LS-100-12 has four M6
mounting threads in the base. It can be mounted on a breadboard at any angle,
by using mounting plate pack LS-100-MP and metric (LS-100-MAS) or imperial
(LS-100-IAS) mounting screws. |