Kontakt Home Home

European Standard Illuminated Laser Warning Signs

WłaściwościIntra beam calculation

 Reduce interruptions and downtime in your laser facility with accurate indication of laser status All Class 3B and Class 4 lasers require interlocking to comply with standard safety practice. However, while this fulfills the safety requirements it can be annoying and even costly to have your laser shut down when an access door is opened. Such interruptions can be avoided either by using a locking interlock system (see ICS-1 brochure), or by providing accurate information regarding your laser status by the use of illuminated signs, or both.

Signs which are left on continuously even when the laser hazard is not present, quickly become ignored, so it is important to use a system incorporating automatic switching. This can be accomplished either directly from the ICS-1 laser interlock control system or by use of the LCU-1 light control unit. Various options are shown below with standard sign panels, but any message can be displayed as required.

Type

Size (mm)

Weight

Power Rating (230 V)

Automatic switching from ICS-1

Automatic switching from LCU-1

One-way sign

360x150x120

2.5 kg

1 x 8 Watt tube

Yes

Yes

Two-way sign

360x300x120

5.2 kg

3 x 8 Watt tubes (two in red section)

Usually (depends on configuration)

Yes

Three-way sign

360x425x120

6.7 kg

4 x 8 Watt tubes (two in red section)

No

Yes







One-way sign

Situation

Switching

Equipment required

1. All situations (recommended setup)

Sign on when laser enabled by interlock system

ICS-1

2. All situations

Sign on only when interlock system switched on

ICS-1

3. All situations

Sign on only when mains power to laser is switched on

None



Two-way sign

Situation

Switching

Equipment required

1. For lasers drawing power from ICS-1

Green section on when ICS-1 on (not reset). Red section on when ICS-1 reset (ie laser enabled)

ICS-1

2. For lasers interlocked via interlock connector or shutter

Green section on when ICS-1 on and laser power supply off. Red section on when ICS-1 on and laser power supply on

ICS-1
Double pole switch for laser power supply

3. All situations

Green section on when ICS-1 on (not reset). Red section on when ICS-1 reset (ie laser enabled)

ICS-1
LCU-1



Alternative two-way sign

 

Situation

Switching

Equipment required

1. All situations

Amber section on when ICS-1 turned on (not reset). Red and Amber sections on when ICS-1 reset (ie laser enabled)

ICS-1



Three-way sign

 

Situation

Switching

Equipment required

1. For lasers interlocked via interlock connector or shutter

Green section on when ICS-1 on. Amber section on when ICS-1 on and laser power supply on. Red section on when ICS-1 reset and laser power supply on.

ICS-1
LCU-1
Double pole switch for laser power supply

Customised sign panels are available

Informacja o zamówieniu

One-way Sign

 Standard one way illuminated laser warning sign

Two-way Sign

 Standard two way illuminated laser warning sign

 

Alternative Two-way Sign

 Alternative two way illuminated laser warning sign

 

Three-way Sign

 Standard three way illuminated laser warning sign

 

Home | Produkty | Kontakt